hi-flame M U LT I F U E L S T O V E S Fitting Instructions Direct Air Box Models EX905, EX907, EX910 EX905 Suitable for HF905-SE Precision I AL905-SE Alpha I GR905 Graphite 5 Use 80mm vent duct (not supplied) EX907 Suitable for HF907-SE Precision II AL907-SE Alpha II GR908 Graphite 8 Use 90mm vent duct (not supplied) www.hi-flame.com Ref: EX905 / UK-NI-ROI / V2.21.10.
PLEASE NOTE If at the time of the spillage tests carried out during commissioning, the stove cannot be confirmed as operating safely, an appropriately sized air vent, as specified in Building Regulations, should be fitted in order to supply additional air for the safe and correct operation of the stove as well as to provide sufficient air for the comfort and safety of the occupants. Under no circumstances should the stove be used until the appropriate air vent has been installed.
INSTALLER HEALTH & SAFETY ATTACHING THE DIRECT AIR BOX During the installation of this stove and any related building works you must comply with current Health & Safety at Work regulations. If you use the correct tools this should only take approximately 30 minutes. The key to this is to use a high-powered drill and preferably new metal drill bits. The stove will be extremely heavy. Adequate facilities must be available for its safe loading, unloading and site handling.
7 Using the 4.0 mm metal drill bit drill all the pilot holes. Use the protective eye wear and ensure that the drill is kept at right angles to the base. 8 Next, use the 5.0 mm drill bit to enlarge these holes. 9 Position the Air Box and line up the Air Box bolt holes with the newly drilled pilot holes and place the first self-tapping metal screw in the middle top bolt hole. Tighten this up with the 8.0 mm socket but do not fully tighten this yet until the remaining bolts are also partly screwed in.
16 Screw the spindle bolt back into the door and attach the primary air control knob. Screw the spindle bolt as far into the knob as it will go being careful not to over-tighten it. Position the knob so that its lugs are horizontal. cause some operational issues, such as smoke spillage, when a stove has been fitted with a direct air supply. Once you understand the cause then such problems can be very easily resolved.
hi-flame M U LT I F U E L S T O V E S Hi-Flame fireplace UK Limited Holmes Chapel Business Park Manor Lane Holmes Chapel Cheshire CW4 8AF www.hi-flame.