3. Fix the flue collar on the outlet which you selected by using the M6 x 20mm flat crosshead
screw. Ensure all seals are secure to prevent air leakage. If you choose the rear flue outlet,
remove the flue cover before fixing the flue collar.
4. Fix the wooden handle on the stainless steel door handle with the M8 x 90mm bolt.
5. Keep the rest of the screws and Allen wrench for future use.
In the unlikely event that something is missing, please contact your dealer immediately.
The floor protection
If the stove is to be installed on a combustible floor, it must be placed on a non-combustible
hearth pad. In the USA, the floor protector must extend 8” beyond each side of the fuel loading
door and 16” to the front (18” to the front in Canada). (See fig. 4)
Floor protection under the stove must be a UL 1618 Type 1 Ember Protector composed of non-
combustible material for protection from radiant heat, sparks and embers.
Individual sections of floor protection must be mortared together to prevent sparks from falling
through to combustible materials. Any carpeting must be removed from under the floor
protection.
16”
In a rear vent installation the floor protection must also extend under the stovepipe and a
minimum of 2” (50mm) beyond either side of the pipe.