User's Manual Part 3

Hi-G-Tek Ltd. Microelectronics & Asset Tracking Technology
144
6
RS 485/232 Communication Protocol
6.5.5.3. Get Results
6.5.5.3.1. Command Transmission
6.5.5.3.2. Get Results Command General Response
The following string is the general response
This command is used to retrieve the results after an RF
communication session.
LSC > Reader
Reader > LSC
STX #B R# CMND(0015h) Channel CRC ETX
1 2 2 2 1 2 1 # of bytes
Channel indicates the source channel for the results. The value is
according to the table in paragraph 5.5.2.1.
STX #B R# MSGT(xx20h) R_status DATA CRC ETX
1 2 2 2 2 n 2
1 # of bytes
channel PK P# Data*
1 1 1 m
# of bytes
Where:
MSGT The high byte of MSGT is according the scenario in
use. The low byte is 20 h.
DATA In case the result is not ready, the value of this field
is 05 hex error code see paragraph 5.4. If the results
are ready, the following applies: