6.5.5.18.2. Execute Saved Command Response
6.5.5.19. Read Channel Definitions Command
6.5.5.19.1. Command Transmission
6.5.5.19.2. Read Channel Definitions Response.
There is no response for this command.
This command allows the reading of the definitions for a device.
LSC > Reader
STX #B R# CMND(0011h) channel CRC ETX
1 2 2 2 1 2 1 # of bytes
is the channel number that the device is connected to.
Channel can be 0 to indicate the MCU, or 1,2 etc for
the other channels.
The following string is the response:
Reader > LSC
STX #B R# MSGT(XX11h) file CRC ETX
1 2 2 2 82 2 1 # of bytes
Where:
File is the data file that defines the device.
File structure is:
Name Size
[bytes]
1 Part number 16
2 Serial number 16
3 Hardware Version 4
4 Production date 10
5 Production Batch number 4
5 Description 32
6 Reserved 45
The format is ASCII