User's Manual

Hi-G-Tek Ltd. Microelectronics & Asset Tracking Technology
62
5
System
(5) This flag is set once one of the flags marked with * in the
LONG STATUS is set. This flag will be reset only if the appropriate
originator flag is reset.
(6) For production use only.
Table 5. 9: Seal Parameters: Defaults and Extreme Values.
# Parameter
Name
Default
value
Minimum
Value
Maximum
Value
Unit Parameter
Length
1
Tag/Seal
Status
- - - 1 Byte
2
Date &
Time
- - - 5 Bytes
3
Seal Stamp - - - 2 Byte
4
# Of Events - - - 1 Byte
5
Version of
firmware
- - - 2 Byte
6
Long
Status
- - - 4 bytes
8
T
w
3000 400 10000 0.977
ms
2 Bytes
9
ADI 00000000 - - 4 Bytes
10
Department 00 - - 1 Byte
11
Tp 10000 400 10000 0.977
ms
2 bytes
12
Tbrs 4096 1024 10240 0.977
ms
2 bytes
13
Alert Bursts
Counter-
Cbrs.
10 0 50 1 byte
14
Alert
Repetition
Rate for Deep
Sleep mode-
Tds
32 3 40 250
ms
1 byte
15
Alert Bursts
Counter for
Deep Sleep
mode-Cds
5 1 50 1 byte
* These flags will set the General Error flag.