User Manual

Chapter 8 System Parameters and Comm ands
- 190 - Hi-G-Tek Ltd. Micro electro nic s & A sset Tra cking Techno logy
Remarks
The following scheme demonstrates the various parts of the Ve ri f y
command t hrough t ime:
t
Reader
Interroga tion
Header - IH
Operating
Interval 1 - I
1
Operating
Interval 2 - I
2
Reader Master
Message -RMM
Receiving
Window
C a li b r at io n
Messages
Window
In t er l ac e
Window
The following scheme demonstrates the various parts of the Receiving
Window through time:
AW
1
AW
2
. . . . . . . AW
Na
RW
1
RW
2
. . . . . . . RW
Nr
TW
1
TW
2
. . . . . . . TW
Nt
Tam per WindowsRandom Windows
Assigned Windows
The RFPa rame te rs class has the following properties:
Name Type Description
Tcm Byte Du rat ion of t he C ali bratio n
Message Window. Units are
1.0 24m s. If 0 – t here's no
Calibration Message Window.
The Calibration Message Window
is us ed al on g with th e
HGTDistanceIndexVerifyMask
fl ag o f t h e Mask argument, to
determine the relative distance of
the DataSeal from the DataReader.
(Default is 0).
Tiw Integer Th e du rati on of th e R eader
Interlace Window. Units are
1.0 24m s. (Defau lt is 0 ).