User Manual

Chapter 8 System Parameters and Comm ands
Hi-G-Tek Ltd. Micro electronics & Asset Tracking Technology - 205 -
the Mult i Addressed Verify: Na,
Nt an d Rt.
StartAddress Integer The starting address of the User
Data to requ est . Thi s argum ent is
relev an t only i f the
HGTUserDataVerifyMask flag is
in cl uded in the Mask argum ent.
Length Byte The length in bytes of the User
Data to requ est . Thi s argum ent is
relev an t only i f the
HGTUserDataVerifyMask flag is
in cl uded in the Mask argum ent.
Result Type
Se als class
Result Description
The returned Se als object contains only the Se al
objects of the DataSeals that responded.
The requested parameters are reflected through the
Se al object s' propert ies.
Remarks
The maximal number of Dat aSeals that can be addressed using t his
command is 7. To address more than 7 DataSeals you can send this
command multiple times, or use a Command Chain.
8.4.3.2 Multi Addressed Commands Without Parameters
All the Multi Addressed commands without parameters can apply up to 8
DataSeals. The result type is always a Seals object that contains only the
DataSeals that have responded. For all the commands their Sh ortS tatu s
property is updat ed according t o their response, and for t he Set, Suspende d
Se t and Soft Set commands also the LongStatus an d SealStamp properties
are updated.