User Manual

Chapter 8 System Parameters and Comm ands
- 206 - Hi-G-Tek Ltd. Micro electro nic s & A sset Tra cking Techno logy
Note: All t he 3 types of set are performed through DataSealLib using t he
Se als.SealSe t method. You specify the type of Set through t he SetO ptions
argument. See the online documentation for further information.
Set
Me thod Se als.SealSet
Description
Prepares the DataSeal for a new use.
Remarks
When a DataSeal receives this command it performs the following actions:
1. Clearing the following Status flags: Ta m p e re d , Low Batte ry
Warning, Opened, Suspen de d Se t an d Sealin g Wi re Ch ange d.
2. Deleting all the Event records from the Events Memory.
3. Write a new Set Event record.
4. The Last Set Reade r paramet er is updat ed.
The Se t command fails in the following situations:
The DataSeal is in Deep Sleep mode.
Li fe Coun te r is 0.
The DataSeal's internal database is corrupted.
The Low Battery Error flag is on.
The Sealing Wire is open.
Suspended Set
Me thod Se als.SealSet
Description
Prepares the DataSeal for a new use.
Remarks