AutoAckBurst Determines whether to send an acknowledge message
automatically to every Burst message the DataReader receives. See section
8.5 above for further information about this flag.
AckBurstRandomDelay Determines whether the DataReader will
choose 1 of 4 windows for the automatic acknowledgment message. See
section 8.5 above for further information about this flag.
Thw
Property Name Thw
Access
Read & Write.
Data Type
Long. Max value: 65535.
Units
3.072msec.
Default Value
997 (3 seconds).
Constant in
H G TRe a de rPa rame te rCo de En um
HGTHFModemThw (45h)
Description
The durat ion of t he Reader
Interrogation Header.
Remarks
See section 8.1.1 for further information about this parameter.
Thp
Property Name Thp
Access
Read & Write.
Data Type
Long. Max value: 65535.
Units
3.072msec.