User Manual

Chapter 6 System Overview
Hi-G-Tek Ltd. Micro electronics & Asset Tracking Technology - 83 -
3. Set Uses to prepare DataSeals for a new use. Sealing Wire must be
attached and closed prior to the Set command. This command can be
sent up t o 8 DataSeals simult aneously.
4. Suspende d Set Similar to the Se t command except that the Sealing
Wire must be open prior to performing the command and the DataSeal
gets set once the Sealing Wire is closed. This command can be sent to
up to 8 Dat aSeals simult aneously.
5. Soft Set Similar to the Se t command, the Soft Set command is used
to prepare DataSeals for a new use. Unlike the Se t command, the Soft
Se t command does not delete the previously recorded Events in the
Event s Memory. This command can be sent t o up t o 8 Dat aSeals
simultaneously.
6. Deep Sleep Puts the DataSeal into Deep Sleep mode. This command
can be sent to up to 8 DataSeals simultaneously.
7. Hard Wakeup Brings DataSeals which are in Deep Sleep mode back
t o normal operat ing mode. This command can be sent to up to 8
DataSeals simultaneously.
8. Start Alert Burst Mode Puts DataSeals into Alert Burst mode. This
command can be sent to up to 8 DataSeals simultaneously, or to all the
receiving DataSeals.
9. Stop Alert Burst Mode Brings DataSeals which are in Alert Burst
mode back t o normal operat ing mode. This command can be sent to up
to 8 DataSeals simultaneously, or to all the receiving DataSeals.
10. Acknowledge Alert Burst – Acknowledges the reception of Alert
Burst messages from Dat aSeals. T he Ac kno wle dge Ale rt Bu rs t
command tells the DataSeal that its message has been received. After
receiving an Ackno wle dge Ale r t Bu rs t command, the DataSeal stops
transmitting its Burst message until a new Tampered event is detected.
This command can be sent to up to 8 DataSeals simultaneously.
11. Read Data Retrieves data from a DataSeals’ User Data area.