7. ATEX Marking
II Equipment Group II: Surface (no-mining) equipment.
2 - Equipment Category 1: Very high degree of protection for use in Zone 0.
G Atmosphere Group: Gases, Vapors, Mists
Ex- Explosion proof equipment: The Equipment that has been certified
for use in a Potentially Explosive Atmosphere
ia - A protection technique based upon the restriction of electrical energy
within the apparatus and in the interconnecting wiring, exposed to a
explosive atmosphere, to a level below that which can cause ignition by
either sparking or heating effects. “ia” - Indicates that the electric circuit is
not able to cause an ignition when there are two failures (“ib” is for a single
failure situation).
IIB - Gas group B: Ethylene - typical gas in petrochemical environment.
T4- Temperature classification (max.135ºC)
Ex ia IIB T4