User's Manual
Table Of Contents
- 1.1.Product Introduction
- 1.2.Product Features
- 1.3.Technical Specifications
- 1.4.Pin introduction
- 1.5.Product packaging
- Figure 1 HLK-B36 package size
- 1.6.Block diagram
- 1.7.Testboard description
- 1.8. Power requirements
- 1.9.WIFI transmission power consumption
- 1.10.WIFI receiving power consumption
- 1.11.Power consumption in each working mode of WIFI
- 1.12.Output power in each mode of WIFI
- 1.13.Receiving sensitivity in each mode of WIFI
- 2.Function description
- 3.ATAT command instructions
- 3.1.Query the current module version:at+ver
- 3.2.Local port operation:at+CLport
- 3.3.Set up the serial port:at+uart
- 3.4.SET DHCP:at+dhcpc
- 3.5.Set wifi connection mode:at+netmode
- 3.6.Set TCP connection mode:at+mode
- 3.7.Set the remote IP when the module is used as a cli
- 3.8.Set the remote port when the module is used as cli
- 3.9.Set parameter submission:at+net_commit
- 3.10.System restart /exit at command mode:at+reconn
- 3.11.Set the ssid and password of the module:at+wifi_co
- 3.12.Set the socket connection protocol:at+remote pro
- 3.13.Set network connection parameters:at+net_ip
- 3.14.Query STA mode network connection status:at+wifi_C
- 3.15.Query module MAC address :at+Get_MAC
- 3.16.Set the framing length:at+uartpacklen
- 3.17.Set framing time:at+uartpacktimeout
- 3.18.Set Bluetooth name:at+ble_name
- 4.AT command control code routine
- 5.Restore factory settings method
- 6.Bluetooth data transparent transmission
- 7.Bluetooth distribution network
- 8.Electrical characteristics
- 8.1.Electrical parameters
- 9.Appendix A Document revision history
第
14
页 共 34 页
returned from the server will be sent to the serial port.
2.7. Application field
Smart home;
Instrumentation;
Wi-Fi remote monitoring/control;
Toy field;
Color LED control;
Intelligent integrated management of fire protection and security;
Smart card terminals, wireless POS machines, handheld devices, etc.。
3. ATAT command instructions
Command format: In the AT command mode, the system can be configured through the AT
command of the serial port. The command format is as follows:
at+[command]=[value],[value],[value]......
All commands start with "at" and end with "\r". If the command is not encapsulated in this
format, it will not be processed, and the module will return different return values according to
different commands.
For example: "at+ver=?"
The module will return: HLK-B36 (b.1.00.120191206180224)
Query command format:
at+[command]=?
3.1. Query the current module version:at+ver
Grammar rules:
Command
type
Grammar
Return and description
Excuting an
order
at+ver=?
at+ver=HLK-B36(b.1.00.120191206180224):current
version