User's Manual

36
Input STN & BS
STN:
KNOWN
I.H:
BS:
T.H:
*Aim BS.
m
m
1
2) Retrieve the point (see the chapter 4.8),then the
display of “STN will be refreshed, at the same
time ,the cursor moves to the input box of
“I.H”(instrument height);
[Note*]:Here, the “STN” can’t be null.
STN: Station name
I.H: Instrument height
T.H: Target height
3) Input the instrument height in the “I.H” input box;
4) Input the name of backsight point, as same as the
operation of “STN” input;
5) Input the target height in the “T.H’ input box, then aim
at backsight point, and press the key [ENT] to enter
the interface of “BS .check 1/2”. As shown below:
BS. check 2/2
DSP
MSR2
MSR1
Z:
m
m
m
E:
N:
BS. check 1/2
Cal HR:
HD:
dHD:
dHR:
m
m
91º4234"
00"00
DSP
MSR2MSR1
[DSP]
[DSP]
6) Press the key [DSP] to switch the display page;
7) Press the key [MSR1] or [MSR2] to start distance
measurement, if the distance measurement is on,it will
be stopped.(Pressing the key [5] can modify the
parameters of measurement). After a successful
measurement, the measured data will be displayed and
you can check by turning pages;