User Manual

memory card). After the static data file must be downloaded to a computer for
processing a static post-processing software.
NOTEWorking mode switch: You can also switch by handheld, please
refer to the specific operation "Hi-Survey Software User's Guide"
equipment Accessibility static capture settings.
Static acquisition step
1. Set up the instrument at the measurement point, the point is to strictly,
and leveling.
2. Measure instrument height three times, each time not more than the
difference between 3mm, take the average as the ultimate instrument height.
High measuring instrument shall be measured to the center point mark stone
on top of the instrument of measurement reference member. V90Plus
receiver measuring reference member 0.130 m radius, phase center height
0.1018m.
figure 3-2
measurement
reference