The environmental operating ranges of the Hiberband modem are defined in table 3.
Table 3: Environmental conditions
2.3 Maximum ESD ratings
The maximum ESD ratings of the Hiberband modem are specified in table 4.
Table 4: ESD ratings
The Hiberband modem is an Electrostatic Sensitive Device (ESD) and requires appropriate
precautions when handling.
2.4 Power supply
The power supply characteristics of the Hiberband modem are specified in table 5.
Table 5: Power supply specifications
Parameter Description Min Typ Max Unit
T
operating
Typical operating temperature +25 °C
Normal operating temperature -30 +70 °C
Extended operating temperature -40 +85 °C
Parameter Max Unit Remarks
ESD sensitivity for all pins except GPS and HB antenna 1000 V Human Body Model according to JESD22-A114
ESD sensitivity for GPS and HB antenna 1000 V Human Body Model according to JESD22-A114
ESD immunity for GPS and HB antenna 4000 V Contact Discharge according to IEC 61000-4-2
8000 V Air Discharge according to IEC 61000-4-2
Parameter Description Min Typ Max Unit
VCC Module supply voltage 3.2 3.3 3.9 V
ICC
peak
Module peak current consumption through all VCC pins,
during transmit burst at maximum power level, with a
matched antenna
1.8 A
Module peak current consumption through all VCC pins,
during transmit burst at maximum power level, with a
mismatched antenna
2.2 A
VREF VREF supply voltage (all ranges) 2.7 3.3 4.5 V
I
REF
Current consumption for voltage reference 3.0 µA