2.5 Current consumption
The current consumption figures of the Hiberband modem are specified in table 6.
Table 6: Hiberband modem current consumption
When designing the application power supply, attention must be paid to the transient behaviour of the Hiberband
modem current consumption when the transmitter power amplifier is turned on. In particular, the Hiberband
transmission burst current consumption (figure 2) pattern needs to be taken into account. For comparison
purposes, the current consumption for transmission of a continuous wave is shown in figure 3.
Figure 2: Hiberband transmission burst current consumption
Figure 3: Hiberband modem transmitter current consumption (continuous wave)
Both patterns were measured with +30 dBm transmission power.
Mode Condition Min Typ Max Unit
Hibernation Mode VCC = 3.3V; VREF = 3.0V 0.5 5 20 µA
Host Communication Mode VCC = 3.3V; VREF = 3.0V 10 20 25 mA
Geo-location Mode VCC = 3.3V; VREF = 3.0V 40 100 120 mA
HiberBand Listen Mode VCC = 3.3V; VREF = 3.0V; max. receive sensitivity 20 23 30 mA
HiberBand Transmission Mode VCC = 3.3V; VREF = 3.0V; max. receive sensitivity and
output power
100 1250 1500 mA