Use and Care Manual

48
NGS Mach II User Guide v1.0
Troubleshooting
General Error Messages
The following is a list of error messages you may encounter when using NGS Mach II and the
suggested action to take to correct the error. IMPORTANT! The suggested actions to take are for
reference only. Always refer to the vehicles shop manual for proper diagnostic procedures.
Message Possible Cause Action to Take
DCL NOT RESPONDING
MODULE NOT RESPONDING
PCM NOT RESPONDING
TCM NOT RESPONDING
Loose link adapter
connection
Incorrect vehicle
and engine
selection
Internal system
error
Vehicle’s link
inoperable
Verify the link adapter is
securely connected and
that the vehicle and engine
selection is correct.
If message recurs, cycle engine
key.
Verify NGS Mach II operates
on a known good vehicle. If
message does not appear,
discontinue testing on the
original vehicle and consult
the shop manual for data link
diagnostics. If message recurs
on a known good vehicle,
contact Hickok technical
support.
Refer to the vehicle’s shop
manual for proper diagnostics.
FATAL SYSTEM ERROR # PLEASE
RESET
Internal system
error.
Disconnect and then
reconnect cables. If message
recurs, contact Hickok
technical support.
NO LINK AVAILABLE ON THIS
VEHICLE
Incorrect vehicle
and engine
selection
Reselect correct vehicle and
engine.
RAM TEST ERROR ADDRESS: # Internal system
error.
Contact Hickok technical
support.