Manual
021-DRC Rev A                           DRC User Manual                           10 
Copyright © High Country Tek, Inc.  2013 
DRC Valve Controller  
Parameter List 
The following table outlines the DRC parameters as well as the limits and units of measure for each parameter. 
Parameter 
Limits 
Units 
DRCx-xxx 
Version # 
C1 Mode 
See Mode Description 
Mode # 
C1 Min input 
-10 to +10.0 
4 to 20.0 
V  
mA 
C1 Max input 
-10 to +10.0 
4 to 20.0 
V  
mA 
C1 Min output 
0 to 600
1
mA 
C1 Max output 
0 to 600
1
mA 
C1 Ramp up 
0.0 to 120.0 
Seconds 
C1 Ramp down 
0.0 to 120.0 
Seconds 
Previous 7 parameters repeated for all channels2 
Dither frequency 
30 to 1000 
Hz. 
C1 Command input 
V (mA) 
C1 Output current 
mA 
Previous 2 parameters repeated for all channels2 
Supply voltage 
Volts 
Fault status 
Fault 
1
0 to 120 mA for 01A version, 0 to 1.2 A for 12A version, 0 to 2.5 A for 25A version
2
Parameters starting with C1 are repeated for each channel and are displayed as C2 to C4 










