User guide
P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools     Page | 106  
Send Uint Name 1 - 4: 
This is the suffix Name for setting the data to the other DVC5/7/10. 
Range: 16 Characters with no spaces. Usable characters are A-Z, a-z, 0-9, and "_". 
Rules: 
The first character cannot be a number. 
 Compiler Keywords or other Names already in use are not valid. 
Re
ceive Uint Name 1 - 4: 
This is the suffix Name for the data sent from the other DVC5/7/10. 
Range: 16 Characters with no spaces. Usable characters are A-Z, a-z, 0-9, and "_". 
Rules: 
The first character cannot be a number. 
 Compiler Keywords or other Names already in use are not valid. 
DVC5/7/10 to 5/7/10 Program Variables 
Name.Status  Set/Get the state of DVC to be communicated with. 
Name.SendName1  Set/Get the current value of that variable. 
Range: 0 to 65535 
Name.SendByte1Bit0,... Name.Sendbyte1.Bit15   
      Set/Get the current bit value of that variable. 
Range: 0 to 1 
Example 
In this example, there are 4 variables that are being sent to another DVC10. The second DVC10’s MAC ID is 
11. The second DVC10 is sent the current RPM, PSI, Set point, and a few Digital inputs. After the second 
DVC10 processes the information, it returns the state of its output. 
First DVC10 Setup: Send to MAC ID 11 
DVC10to10.Send_RPM = Ana_1 
DVC10to10.Send_PSI = Uni_1 
DVC10to10.Send_Setpoint = 22% 
DVC10to10.Send_Bits.Bit0 = Dig_1 
DVC10to10.Send_Bits.Bit1 = Dig_2 
Receive from MAC ID 11 
Var = DVC10to10.Receive_Output 
Second DVC10 Setup: Send to MAC ID 10 
DVC10to10.Send_Output = PWM_1 
Receive from MAC ID 10 
PWM_1 = 
(DVC10to10.Rec_RPM/3)+(DVC10to10.Rec_PSI /3) 
PWM_2 = DVC10to10.Rec_Setpoint 
HS1 = DVC10to10.Rec_Bits.Bit0 
HS2 = DVC10to10.Rec_Bits.Bit1