User guide
P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools     Page | 122  
7.8  Input / Output Functions 
Dou
ble click the IO Functions yellow button (in the middle of 
the Monitor window) to activate this window. The information 
displayed is the same as the information programmed with the 
HCT Programming Tool. The user can alter the Input% vs. 
Output%. The information will be updated to the DVC5/7/10 
temporary memory once the Send Changes button has been 
pressed. The DVC5/7/10 then operates on the temporary 
values until the unit has been reset. 
Note: The temporary memory can be saved to a file and 
imported into the HCT programming tool by using the “Export 
to File” button. 
7.9 Factory Information 
Dou
ble click the Factory Info yellow button (in the middle of 
the Monitor window) to activate this window. The information 
displayed is programmed by HCT manufacturing. 
Note: If you change the CAN Bus baud rate for the 
DVC5/7/10 you should also change all of the baud rates for 
the other modules on the CAN Bus. If you change the 
DVC5/7/10 MAC ID then be sure you assign it a number that 
is unique with respect to the other modules on the CAN Bus. 
7.10 EE memory 
Double click on the EE 
memory Status icon on the 
main Program Loader 
Monitor window to activate 
this screen. EE memory is non-volatile (i.e. it retains the value even when 
power is turned off). Memory variable names and values are set using the 
Programming Tool or as the program executes. The selector at the top of the 
screen will allow you to page through the variables. You can change the 
variables integer values using the up and down arrows next to the variable’s 
name. The new values can be sent to the DVC5/7/10 EE memory by selecting 
the Send Changes button. Additionally, the Save to File button allows the user 
to save the EE variables and their respective values to a .DAT file on the PC. 
The Restore from File button allows the user to recall previously saved EE 
variable values from a .DAT file. The Push to Retrieve button initiates the 
Restore operation after the Restore From File button is selected. 