User guide
P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools     Page | 126  
7.15  DVC61 (Display Module) and the Loader Monitor 
The following screen appears when connected directly to 
the DVC61. This screen enables the user to monitor the 
status of the Inputs, Baud rate, Supply Voltage, Serial 
Number and MAC ID as well as changing some of the 
features of the DVC61. When viewing this screen while 
connected to the DVC5/710 certain features will be “grayed 
out” because changes cannot be sent to the DVC61 
through the DVC5/7/10. 
MAC ID 
This setting is used to set the modules address for 
communication on the CAN Bus. Possible values range from 0 to 63 and the user must select “Send Changes” 
to invoke a change. 
Caution: If the MAC ID is changed to a value different from that in the Programming Tool’s DVC61 configuration 
screen and the Send Changes button is pressed, the new value will be saved to temporary memory. If the 
DVC7/10 is plugged in, it will not recognize or be able to communicate with the DVC61 until the application is 
changed and reloaded onto the DVC7/10. 
Baud Rate 
This pull down menu is used to select between different CAN Bus communication rates. Possible values are 
125Kps, 250Kps and 500Kps, the user must select “Send Changes” to invoke a change. 
Caution: If the baud rate is changed to a value different than the rate in use by the DVC7/10 and the Send 
Changes button is pressed, the new value will be saved to temporary memory. If the DVC7/10 is plugged in, it 
will not be able to communicate with the DVC61 until its baud rate is changed to match that of the DVC61 using 
the Program Loader Monitor factory info window. 
Default LCD Contrast / Backlight 
Changing these settings and selecting “Send Changes” will reset the default values for Contrast and Backlight 
levels for this unit. 
Default Screen / Blank Screen 
This pull down menu is used to select between the “High Country Tek” default screen and a “Blank” screen to be 
displayed at power up until the application writes its own screen to the display module. The user must select 
“Send Changes” to invoke a change. 
CAN Terminating Resistor On / Off 
This pull down menu is used to set whether the internal CAN Bus terminating resistor is active or not. The user 
must select “Send Changes” to invoke a change. 
Display Screen (Button) 
This switch allows the user to toggle between monitoring the unit’s settings and monitoring the current screen 
being displayed by the application. 