User guide
P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools     Page | 143  
* For Active High connections, the SPST switch will be connected between   
 the appropriate input and (+) power.       
* For Active Low connections, the SPST switch will be connected between   
 the appropriate input and ground.       
10.9 DVC70 Hardware Connections 
DVC70         
18 Pin Metri-Pak connector (P12)       
Pin Function  Pin Function     
A1 RXD  D1       
A2 TXD  D2       
A3 RTS  D3       
B1  SIG COM  E1  (-) PWR BAT     
B2    E2  (+) PWR IGN     
B3    E3  ALARM OUT     
C1    F1  PWR COM     
C2    F2  PWR COM     
C3    F3  PWR COM     
DVC70         
5 Pin J1939 connecter (P13)         
Pin Function        
1 NC        
2 NC        
3 NC        
4 CAN H        
5 CAN L        
10.10 DVC80 Hardware Connections 
DVC80         
18 Pin Metri-Pak connector (P14)       
Pin Function  Pin Function     
A1  RXD  D1  J1939 CAN H     
A2  TXD  D2  J1939 CAN L     
A3  SIG COM  D3       
B1  SIG COM  E1  (+) POWER IN     
B2  (+) 5VDC  E2       