User guide
P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools     Page | 23  
(2) valves, 1.7A each  3.4A 
Total current    3.55A 
  Of course, a AGC fuse of 3.55A is not available, use a fuse size near this calculated value. 
2 Software Installation 
2.1 System Requirements 
Windows XP Professional 
Windows Vista Business or Ultimate 
40 megabytes of disk space to support a complete system install 
PC with Serial Port - RS232 or USB port 
For USB ports you need a USB to RS232 converter (i.e. Dongle) 
DVC5/7/10 controller module 
DVC10 serial cable 
2.2 Installation 
Whe
n you install the DVC development software following the steps outlined here you will have one 
Programming Tool and one Program Loader Monitor that supports both the DVC5 and the DVC10. 
To install the DVC development software, close all program applications. Insert the DVC Software CD in the 
CD-ROM drive, and wait for the installer program to execute. The installer will guide you through the installation 
procedure. 
2.3 Software Overview 
The DV
C software package includes two applications named "Programming Tool" and "Program Loader 
Monitor". These applications provide the means to configure, design, create, load, and monitor the user 
application. The Programming tool is  used to 
configure the inputs and outputs and 
program the control logic for an 
application. The Program Loader  Monitor 
is used to download the user 
application program files to the 
DVC5/7/10. It also performs real time 
monitoring of your system 
inputs/outputs. Also, you can modify  some 
input/output configuration settings (i.e.  like 
analog ramp rates). Another feature  of the 
Program Loader Monitor is it allows  you to 
see and change EEmem variable 
settings. For example, this is a 
convenient way to have the user  interact 
with the system to change a 
maximum pressure setting or input a 
customer job number as the system is 
running. 
Programming Tool 