Name.LOS  Loss of Signal flag set after time out. For 
Universal Pulse inputs Only 
False (Pulses ok), True (No 
Pulse Input) 
Name.RealRPM  The Unsigned Integer Value of the RPM. For 
Universal Pulse inputs Only 
0 to 9999 
Name.Counter  Get/Set Unsigned Integer Value of the Counter. 
Universal Pulse inputs Only 
0 to 65535 
Name.PulsesPerRev  Get/Set Pulses Per Revolution  0 to 9999 
Output Group Selected as Dual Coil High-Side 
Name Description  Range 
(Low-Side/PWM) Name  Set  the state Current Target or 
Process in percentage of min to max 
current 
0% to 100% 
Name.Dir  Set the coil to be PWM’d, *(use High 
Side names to set the direction) 
High-Side Odd # Name / High 
Side Even # Name 
Name.Enable  Set the PWM to 0 or enable the PWM  True  [PWM  Enabled],  False 
[PWM = 0] 
Name.Short  Get the Coil Flag for Short Status  Off [Coil Ok], On [Coil Short] 
Name.Open  Get the Coil Flag for Open Status  Off [Coil Ok], On [Coil Open] 
HSEven#Name.Rampup  Set the ramp up rate (time to travel 
from 0% to 100%) 
0.0 to 65.00 s 
HSEven#Name.Rampdown  Set the ramp down rate (time to travel 
from 100% to 0%) 
0.0 to 65.00 s 
HSEven#Name.Short  Get the Coil Flag for Short Status  Off [Coil Ok], On [Coil Short] 
HSEven#Name.Open  Get the Coil Flag for Open Status  Off [Coil Ok], On [Coil Open] 
HSOdd#Name.Rampdown  Set the ramp down rate (time to travel 
from 100% to 0%) 
0.0 to 65.00 s 
HSOdd#Name.Short  Get the Coil Flag for Short Status  Off [Coil Ok], On [Coil Short] 
HSOdd#Name.Open  Get the Coil Flag for Open Status  Off [Coil Ok], On [Coil Open] 
Name.Cur  Current actual * CurGain = amps  0 – 3.5 amps 
Name.RampCur  Ramped Current*CurGain= amps  0 – 3.5 amps 
Name.CurErr  Current Error = RampCur – Cur  16 bit signed integer 
Name.CurSumErr  Current Error accumulated over time  0 – 65535 
Name.CurP  Current Proportional Term Constant 
“P” 
0 – 255 
Name.CurI  Current Proportional Term Constant 
“I” 
0 – 255 
Name.MinCurA  Minimum Current Coil A *.001 = amps 0 – 3.5 amps 
Name.MaxCurA  Maximum Current Coil A *.001 = 
amps 
0 – 3.5 amps 
Name.MinCurB  Minimum Current Coil B *.001 = amps 0 – 3.5 amps 
Name.MaxCurB  Maximum Current Coil B *.001 = 
amps 
0 – 3.5 amps 
Name.Config  Configuration Word –Output, 
Process, Coil 
1
Name is the actual name entered in the Input/Output configuration window. 
2
Scale depends on Input Range (0 to 5 =.00489, 0 to 10 = .00977, 0 to 25ma = 0.02158 ) 