User guide
P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools     Page | 53  
from 100% to 0%) 
Name.Frequency  Set PWM frequency  0 to 1000 for 0 to 100hz 
Name.Dutycycle  Ser PWM dutycycle  0 to 1023 for 0 to 100% 
Name.Freqerror  Returns error 1 = Frequency error, 
2 means duty cycle error 
HSEvenName  Set the Bang-bang Coil to On or Off  Off, On 
HSEven#Name.Short  Get the Coil Flag for Short Status  Off [Coil Ok], On [Coil 
Short]
HSEven#Name.Open  Get the Coil Flag for Open Status  Off [Coil Ok], On [Coil 
Open]
HSOddName  Set the Bang-bang Coil to On or Off  Off, On 
HSOdd#Name.OpenDisable
  Set the Disable Coil Open Detection  0 [Enabled], 1 [Disabled] 
HSOdd#Name.Short  Get the Coil Flag for Short Status  Off [Coil Ok], On [Coil 
Short]
HSOdd#Name.Open  Get/Set the Coil Flag for Open Status  Off [Coil Ok], On [Coil 
Open]
Name.Cur  Current actual * CurGain = amps  0 – 3.5 amps 
Name.RampCur  Current ramped Currend*CurGain= amps  0 – 3.5 amps 
Name.CurErr  Current Error = RampCur – Cur  16 Signed Integer 
Name.CurSumErr  Current Error accumulated over time  0 – 65535 
Name.CurP  Current Proportional Term Constant “P”  0 – 255 
Name.CurI  Current Proportional Term Constant “I”  0 – 255 
Name.MinCurA  Minimum Current Coil A *.001 = amps  0 – 3.5 amps 
Name.MaxCurA  Maximum Current Coil A *.001 = amps  0 – 3.5 amps 
Name.Config  Configuration Word – Output, Process, 
Coil 
Output Group Selected as PWM Disabled 
Name Description  Range 
HSEvenName
  Set the Bang-bang Coil to On or Off  Off, On 
HSEven#Name.OpenDisabl
e 
Set the Disable Coil Open Detection  0 [Enabled], 1 [Disabled] 
HSEven#Name.Short
  Get the Coil Flag for Short Status  Off [Coil Ok], On [Coil 
Short]
HSEven#Name.Open  Get the Coil Flag for Open Status  Off [Coil Ok], On [Coil 
Open]
HSOddName  Set the Bang-bang Coil to On or Off  Off, On 
HSOdd#Name.OpenDisabl
e
Set the Disable Coil Open Detection  0 [Enabled], 1 [Disabled] 
HSOdd#Name.Short  Get the Coil Flag for Short Status  Off [Coil Ok], On [Coil 
Short]
HSOdd#Name.Open  Get/Set the Coil Flag for Open Status  Off [Coil Ok], On [Coil 
Open]
Enable Process PI Variables 
The Name field is the Low-Side name. The default variable name is replaced with the specified name. 
Name Description  Range 
Name.Setpoint
  The desired % set point position for the 
output
0 to 100% 
Name.Feedback  The % feedback position for the output  0 to 100% 
Name.ProErr  Error = Set point – Feedback  16 bit signed integer 
Name.ProSumErr  Error accumulated over time  0 – 65535 
Name.ProP  Process Proportional Term Constant “P”  0 – 255 