Name.ProI  Process Proportional Term Constant “I”  0 – 255 
Name.ProItime  Update / Integration Time  0.0 to 650.00 s 
Name.Cur  Current actual * CurGain = amps  0 – 3.5 amps 
Name.RampCur  Current ramped Currend*CurGain= amps  0 – 3.5 amps 
Name.CurErr  Current Error = RampCur – Cur  16 bit signed integer 
Name.CurSumErr  Current Error accumulated over time  0 – 65535 
Name.CurP  Current Proportional Term Constant “P”  0 – 255 
Name.CurI  Current Proportional Term Constant “I”  0 – 255 
Name.MinCurA  Minimum Current Coil A *.001 = amps  0 – 3.5 amps 
Name.MaxCurA  Maximum Current Coil A *.001 = amps  0 – 3.5 amps 
Name.MinCurB  Minimum Current Coil B *.001 = amps  0 – 3.5 amps 
Name.MaxCurB  Maximum Current Coil B *.001 = amps  0 – 3.5 amps 
Name.Config  Configuration Word – Output, Process, 
Coil 
Status LED 
Name Description  Range 
BlinkCode
  The Status LED blinks the amount of times equal to the number 
written to this location. When the blinking is done, the value for this 
location will be 0.
0 to 65535 
Input/Output Functions 
Name De
scription  Range 
Name.In
  Changing this variable will update the "Name.Out" 
variable by the BIOS after a delay of 10ms
0% to 100% 
Name.Out  The Output of the Transfer Function  0% to 100% 
Name.X0  The X0 of the input/output function  0% to 100% 
Name.X1  The X1 of the input/output function  0% to 100% 
Name.X2  The X2 of the input/output function  0% to 100% 
Name.X3  The X3 of the input/output function  0% to 100% 
Name.X4  The X4 of the input/output function  0% to 100% 
Name.X5  The X5 of the input/output function  0% to 100% 
Name.X6  The X6 of the input/output function  0% to 100% 
Name.X7  The X7 of the input/output function  0% to 100% 
Name.Y0  The Y0 of the input/output function  0% to 100% 
Name.Y1  The Y1 of the input/output function  0% to 100% 
Name.Y2  The Y2 of the input/output function  0% to 100% 
Name.Y3  The Y3 of the input/output function  0% to 100% 
Name.Y4  The Y4 of the input/output function  0% to 100% 
Name.Y5  The Y5 of the input/output function  0% to 100% 
Name.Y6  The Y6 of the input/output function  0% to 100% 
Name.Y7  The Y7 of the input/output function  0% to 100% 
Power Supply 
Name  Description 
Supply  The Power Supply voltage. The value returned is in units of supply volts (sv) 
Temperature 
Name  Description 
DVC_Temperature  Internal DVC5/7 controller temperature. The value returned is in units of 
degrees C + 40. Therefore, –40 C is returned as 0. 
Continuous Counter 