P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools     Page | 94  
6.8 DVC65 
The DVC65 layout screen is similar to that of the DVC61 except it is 
limited to 2 rows of 24 characters each. New DVC65 screens can be 
defined by first clicking the right mouse button in the window and 
selecting "Add Screen". 
DVC65 Screens  
A DVC65 Setup screen has a field to change the Name, display up 
to 4 Variables, and a string of text. In the upper portion 
(2x24 Test Display) of the setup screen, there is a preview of 
the DVC65 display. 
Name: 
The name used in the bubble logic to access this screen and 
its properties. 
16 Alpha/Numeric characters only with no spaces 
V1, V2, V3 & V4 
Type 
Refer to Section 8.2 for an explanation of Display Types. 
X & Y 
These are the X and Y Coordinates for the Displayed 
Variables. 
The Upper left corner is X = 1 and Y = 1 
Test Value 
This is the value displayed on the test screen to allow the user to preview the finished screen while in the 
programming tool. 
DVC65 Program Variables 
Name.Status  Get the state of the flag. 
Range: 0 = Module is Online 
    2 = Module is Offline 
Name.Screen    Set the screen name 
Range: Every defined Screen 
Name.V1    Set the value for the Var 1 
Range: 0 to 65535 
Name.V2    Set the value for the Var 2 
Range: 0 to 65535 