User guide
P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools     Page | 99  
Range: 1 - 5 = Memory Bucket # (1 – 5) Active 
DVC70.AlarmState 
Range: 1 – 5 = Alarm State for Memory Bucket 1 – 5 
DVC70.PercentUsed 
Possible Values: 50%, 60%, 70%, 80%, 90%, 95%, 98%, and 100% 
DVC70.MinSec 
Bits: bits 0 – 6 (Seconds) – 0 - 59 
       bits 8 – 15 (Minutes) – 0 - 59 
DVC70.DayHours 
Bits: bits 0 – 4 (Hours) – 0 - 23 
       bit 5 PM or AM – 0 or 1 
       bit 6 12 or 24 hour clock – 0 or 1 
 bits 8 – 15 (Day of the Week) – 1 - 7 
DVC70.MonthDate 
Bits: bits 0 – 5 (Date) – 1 - 31 
       bits 8 – 13 (Month) – 1 - 12 
DVC70.Year 
Bits: bits 0 – 7 (Year) – 00 - 99 
Memory Bucket Name       
Range: 1 Name per Memory Bucket 
Memory Bucket Name.VarName1 – 10 (Trend only) 
Range: 1 Name per Variable 
Memory Bucket Name.VarName1 – 5 (Event or Fault) – the application programmer uses this variable to set up 
the Message to be displayed if the event becomes true and to set up the Scaling factor 
Range: 1 Name per Variable 
SF1 – 12     
Possible Values: SF1 = 0 = None 
     SF2 = 4096 = 1:1 
     SF3 = 8192 = -1 Volt to 1 Volt 
     SF4 = 12288 = 0 Volts to 5 Volts 
     SF5 = 16384 = 0 Volts to 10 Volts 
     SF6 = 20480 = 4 ma to 20ma 
     SF7 = 24576 = Supply Volts 
     SF8 = 28672 = True / False 
     SF9 = 32768 = On / Off 
     SF10 = 36864 = 0.1 
     SF11 = 40960 = 0.01 (s) 
     SF12 = 45056 = 0.001 
Memory Bucket Name.Data1 – 5 (Event or Fault) 
Range: 1 Data point for each Variable (1 – 5) 