Instruction Manual
7.1  EE memory when online (PLM) 
Double click on the EE memory Status icon on the main Program Loader Monitor window to activate this screen. 
EE memory is non-volatile (i.e. it retains the value even when power is turned off). Memory variable names and 
values are set using the Programming Tool or as the program executes. The selector at the top of the screen 
will allow you to page through the variables. You can change the variables integer values using the up and down 
arrows next to the variable’s name. The new values can be sent to the DVC5/7/10 EE memory by selecting the 
Send Changes button. Additionally, the Save to File button allows the user to save the EE variables and their 
respective values to a .DAT file on the PC. The Restore from File button allows the user to recall previously 
saved EE variable values from a .DAT file. The Push to Retrieve button initiates the Restore operation after the 
Restore From File button is selected. 
PN 021-00154-QSG, Rev A.2  Quick Start Guide    Page | 12  