Digital Inputs
Name Description Range
Name Set/Get the state of the switch False or Off, True or On
Name.RealRPM
The Unsigned Integer Value of the RPM.
For Pulse inputs Only
0 to 9999
Name.PulseTimeout Get/Set Pulse Timeout for Loss of Signal 0 to 65535
Name.PulsesPerRev Get/Set Pulses Per Revolution 0 to 9999
Name.Counter
Get/Set Unsigned Integer Value of the
Counter. Pulse inputs Only
0 to 65535
Name.LOS
Loss of Signal flag set after time out. For
Pulse inputs Only
False (Pulses ok), True (No Pulse
Input)
High Side Only
Name Description Range
HSEvenName Set the Bang-bang Coil to On or Off Off, On
HSEven#Name.OpenDisable Set the Disable Coil Open Detection 0 [Enabled], 1 [Disabled]
HSEven#Name.Short Get the Coil Flag for Short Status Off [Coil Ok], On [Coil Short]
HSEven#Name.Open Get the Coil Flag for Open Status Off [Coil Ok], On [Coil Open]
HSOddName Set the Bang-bang Coil to On or Off Off, On
HSOdd#Name.OpenDisable Set the Disable Coil Open Detection 0 [Enabled], 1 [Disabled]