Process PI Variables
Name Description Range
Name.Set-point
The desired % set point position for the
output
0 to 100%
Name.Feedback The % feedback position for the output 0 to 100%
Name.ProErr Error = Set point – Feedback 16 bit signed integer
Name.ProSumErr Error accumulated over time 0 – 65535
Name.ProP Process Proportional Term Constant “P” 0 – 255
Name.ProI Process Proportional Term Constant “I” 0 – 255
Name.ProItime Update / Integration Time 0.0 to 650.00 s
Name.Cur Current actual * CurGain = amps 0 – 3.5 amps
Name.RampCur Current ramped Currend*CurGain= amps 0 – 3.5 amps
Name.CurErr Current Error = RampCur – Cur 16 bit signed integer
Name.CurSumErr Current Error accumulated over time 0 – 65535
Name.CurP Current Proportional Term Constant “P” 0 – 255
Name.CurI Current Proportional Term Constant “I” 0 – 255
Name.MinCurA Minimum Current Coil A *.001 = amps 0 – 3.5 amps
Name.MaxCurA Maximum Current Coil A *.001 = amps 0 – 3.5 amps
Name.MinCurB Minimum Current Coil B *.001 = amps 0 – 3.5 amps
Name.MaxCurB Maximum Current Coil B *.001 = amps 0 – 3.5 amps
Name.Config
Configuration Word – Output, Process,
Coil
P/N: 021-00163, Rev. A.0 - for V5.2 Tools Page | 47