Software User guide
Electronic Controller Solutions for the Global Fluid Power Industry 
epc-2 & evc-2 Specification Overview ( General ): 
1.  Module size/format:          High Country Tek Inc. Mobile ‘easy-mount’ format 
2. Design Standards:  Full CE classification 
3.  Power Supply type and range:        10 to 32VDC (max) 
4.  Recommended module protection:      5A AGC fuse in power supply line 
5. User stabilized voltage:  + 5VDC ±10% 
6. Output current:  500mA (max) 
7. Protection:  Current limited, short circuit protected 
8. Digital Input number:  3x ON/OFF inputs 
9. Digital Input type:  DCV - level shift  
10. Digital input values:           0V to +VPower supply max 
11. Universal input number:  2x inputs 
12. Universal input type:          DC voltage or DC Current 
13. Universal input values:          0 to +5v or 4 to 20mA 
14. Voltage Command I/P Impedance:        10 KOhm 
15. Current command shunt resistor value:      100 Ohms 
16. Proportional Output number:  2x PWM 
17. Protection:  Open and short circuit protection 
18. Proportional output Current:  0 to 3 amps max 
19. Digital Output number:  6x High Side 
20. Digital output type:  ON/OFF level shift 
21. Proportional output Current:  0 to 3 amps max 
22. Protection:  Open and short circuit protection 
23. Digital output values:          0V to +V module supply voltage -0.5VDC 
24. Operating Temperature range:  -40C to +85C 
25. Storage temperature range:  -40C to +100C 
26. Ingress protection rating:          IP 68 / NEMA 6P 
27. Connector type:  Metri-Pack 30 way male  
REMOTE ENABLE Important Note: 
 The Enable input is DIGI 1 ( connector pin S2 ) and is configured to be active HIGH 
 The user MUST pull the input ‘S2’ to +V supply to allow normal operation. 
 The enable input is failsafe, with the input pin ‘S2’ pulled LOW ( 0V ) internally. 
Contact HCT customer service or your nearest HCT Product distributor for other 
connection/Hardware configurations if required 
3 