Manual

023-00354-Rev1.6 evc/epc User Manual 11
Copyright © High Country Tek, Inc. 2013
evc/epc Controller
With SAE J1939 Interface
evc/epc GUI Overview
File
All changes made through the GUI are temporary until saved permanently.
Permanently save settings to unit: Save the settings to the units EEPROM (permanent memory).
Permanently save settings to unit & file (.dat): Permanently save the settings to the units EEPROM and to a
data file that may be uploaded into any evc/epc controllers later.
Settings will be lost if not permanently saved before power cycle.
To reset the unit with a power cycle, you must remove both the USB cable and DC power from the unit.
Restore unit to last permanent settings saved: Reload settings stored in the EEPROM. This will undo all
changes made since the last Permanent Save.
Restore unit settings from data file (.dat): Load the data file from the PC to the evc/epc.
Restore unit from v1.03 data file: Load the previous version data file from the PC to the evc/epc.