Manual
023-00354-Rev1.6                         evc/epc User Manual                          33 
Copyright © High Country Tek, Inc.  2013 
evc/epc Controller  
With SAE J1939 Interface 
  When the measured RPM is above the RPM oil A current is determined by the Fixed Set-
point.  
  
measured RPM.  
  Coil A current becomes zero when the measured RPM reaches RPM  
  W-OFFstays at 0 until the 
increase proportionally to the measured RPM. 
RPM Stop RPM Slow Engine rpm
Coil A Current @ 
fixed Set-point
Anti-stall starts
Coil Current
0
Anti-stall 
full effect
  WAuto-ONCoil B current will ramp up to the Reverse Set-
point. 
  After the reverse cycle is over, if the measured RPM increases to above RPM Stop, Coil A current increases 
proportionally until reaching the fixed  set-point. If not, the evc/epc will  re-   Reverse Retry 
Count times, each time remaining in reverse for ime 
  If the Reverse Retry Count is depleted and the measured RPM remains below RPM Stop, the evc/epc will 
declare an error and output the default settings to coil A. 
RPM Stop RPM Slow Engine rpm
Coil A Current @ 
fixed Set-point
Anti-stall starts
Coil Current
0
Anti-stall 
full effect
Coil B Current @ 
reverse Set-point










