evc/epc Controller  
With SAE J1939 Interface 
SAE J1939 CAN Bus 
The evc/epc can be controlled by messages received over the SAE J1939 Bus. 
The EEC1 (PGN: 61444 SA: 0) engine RPM (SPN: 190) can be monitored for use in anti-stall and closed loop 
operations. 
The proprietary SAE J1939 Command Message (PGN: 65281 through 65407 SA: 34) can be monitored for Coil A, 
Coil B and RPM Set points for various operation modes. This address is adjusted based on the Module ID. The 
relationship of the Module ID and the Command Message address is defined in a chart at the end of this section.  
The evc/epc can transmit its status over the SAE J1939 Bus. 
The proprietary SAE J1939 Status Message (PGN: 65409 through 65535 SA: 34) is a multiplexed message with 
the first data byte indicating message 1 Status or message 2 Analog Values. This address is adjusted based on the 
Module ID. The relationship of the Module ID and the Status Message address is defined in a chart at the end of 
this section. When the SAE J1939 Command Message is enabled, the Status Message will be transmitted. If 
Report Analog Values is enabled on the SAE J1939 tab, the Analog Values will be transmitted. The content of the 
Status and Analog Values messages are detailed below. 
Command Message Format 
Transmission Repetition 
40mS 
Data Length 
8 
Data Page 
0 
PDU Format 
255 
PDU Specific 
Module ID # 
Priority 
N/A 
Parameter Group Number 
65281 Through 65407 
(FF01 Through FF7F) 
Start Position 
Length 
Parameter Name 
1 
1 Byte 
Always = 1 
2-3 
2 Bytes 
Coil A Set point 
4-5 
2 Bytes 
Coil B Set point 
6-7 
2 Bytes 
RPM Set point 