MVP-SVR Power Saver Valve Controller  
MVP-SVR Controller 
The MVP-SVR controller drives proportional solenoid valves with high starting current then reduces it to a lower 
operating level. Operating power is reduced thereby saving energy, reducing heat and extending coil life.  
Once configured, the settings are permanently stored in the controller memory. 
MVP-SVR Features 
  Easily configured using HCT Graphical User Interface (GUI) or HCT Hand Held Interface (HHI) 
  LED indication of power, output current and fault status 
  Permanently sealed, standard DIN 43650 Form A connector body with pre-wired 18AWG PVC cable 
  Single coil applications 
  Adjustable output with short circuit protection  
  Start current and hold current are independently adjustable 
  Adjustable start time 
Operating Specifications 
Supply Voltage 
9 to 28VDC 
Supply Current 
Valve current + 20mA (Quiescent Max) 
Output Current 
-06A: 600mA MAX 
-12A: 1.2A MAX 
-25A: 2.5A MAX 
Coil Resistance 
2 MIN. 
Operating Temperature Range 
-20º to 70º C (operating); -40º to 85º C (storage) 
Enclosure 
Glass filled Nylon 
Dimensions 
Inch: 2.4 L x 1.2 W x 0.75 H; Mm: 60 L x 30 W x 19 H 