Technical Data

High Performance Cement by Quikrete
®
www.highperformancecement.com • (800) 388-4338
FastSet
All-Crete
Installation
INSTRUCTION FOR USE AS A GROUT
MIXING
FastSet
All-Crete
should be mechanically mixed for a
minimum of 3 minutes. WEAR IMPERVIOUS GLOVES,
such as nitrile when handling product.
Use the minimum amount of water necessary to
provide the desired ow (approximately 13 pints (6.1
L) for a uid consistency)
Do not exceed a flow of 20 seconds by ASTM C939
Add most of the mixing water to the mixer rst
Add the powder to the water and adjust as needed
to achieve the desired consistency
For a owable consistency, reduce the water content
to approximately 11 pints (5.2 L) per bag
PLACEMENT
Surfaces to receive the grout must be clean and free
of any type of foreign matter, grease, paint, oil, dust or
efflorescence. In some cases, it may be necessary to
roughen smooth surfaces or etch old ones with acid.
The area should be thoroughly flushed and soaked
with clean water prior to grouting, leaving no standing
water. Place the grout quickly and continuously using
light rodding to eliminate air bubbles.
CURING
A damp cure of at least 1 day is necessary to control
the non-shrink characteristics and maintain strength
levels.
WORKING TIME
When properly mixed to a fluid consistency, FastSet
All-Crete
will fully comply with ASTM C1107 and retain
a fluid consistency for 20 minutes at 70 degrees F (21
degrees C).
TEMPERATURE
Grout temperature should be maintained at 50 - 90
degrees F (10 - 32 degrees C) for best results. To
achieve specified performance in accordance with
ASTM C1107, maintain temperature as close to 70
degrees F (21 degrees C) as possible. Use cold water
in hot weather and hot water in cold weather to
achieve desired grout temperature. Do not pour grout
if temperature is expected to go below 32 degrees F
(0 degrees C) within a 12 hour period.
INSTRUCTIONS FOR USE AS A REPAIR MORTAR
MIXING
FastSet
All-Crete
should be mechanically mixed
for a minimum of 3 minutes. WEAR IMPERVIOUS
GLOVES, such as nitrile when handling product.
Use the minimum amount of water necessary to
provide a slump of about 3- 6” (76-152 mm). Add
approximately 7.5 pints (3.5 L) of water to the mixer
first. Add the powder to the water and adjust as
needed to achieve the recommended consistency. For
repairs deeper than 2(51 mm), add 25 lb (11.3 kg) of
high quality gravel with a top size of 1/2(13 mm) or
less to the mix. Mix water will vary depending on the
dampness of the aggregate. Do not add more water
than needed to achieve a slump of 3” - 6” (76-152 mm).
SURFACE PREPARATION
Remove all spalled areas and areas of unsound
concrete and patching
The hole should have a vertical edge of 1/2(12.7
mm) or more, formed by use of a pneumatic
jackhammer or sawing. Holes should be chipped out
to create a new, sound substrate
After the chipping process is completed, the repair
area must be cleaned by water blasting or other
suitable method
Dampen holes with clean water before patching. No
puddles of water should be left in the hole
PLACEMENT
The hole should be filled by placing material full
depth, from one end to the other to eliminate part
depth lifts between batches
Consolidate the material in the hole by hand
tamping or chopping with a shovel. This is
particularly important around the edges
Screed and nish patches with hand tools to create a
surface finish equivalent to the existing slab nish
CURING
No special curing procedures are required. Curing at
ambient conditions is preferable.
Warranty
The QUIKRETE
®
Companies warrant this product
to be of merchantable quality when used or applied
in accordance with the instructions herein. The
product is not warranted as suitable for any purpose
or use other than the general purpose for which it is
intended. Liability under this warranty is limited to the
replacement of its product (as purchased) found to
be defective, or at the shipping companies’ option,
to refund the purchase price. In the event of a claim
under this warranty, notice must be given to The
QUIKRETE
®
Companies in writing at: One Securities
Centre, 3490 Piedmont Road, Suite 1300, Atlanta, GA
30305. This limited warranty is issued and accepted
in lieu of all other express warranties and expressly
excludes liability for consequential damages.