Technical Data

High Performance Cement by Quikrete
®
www.highperformancecement.com • (800) 388-4338
TABLE 1 Typical Physical Properties
FastSet
All-Crete
Tested as a Grout
Consistency Fluid Flowable Plastic
Approximate water content per bag 13 pints (6.1 L) 11 pints (5.2 L) 7 1/2 pints (3.5 L)
Flow, ASTM C939
Flow, at 5 drops, ASTM C1437
Working time
Setting time Final, ASTM C191
20 - 30 sec
-
About 20 min
20 - 45 min
-
125 - 145
About 15 min
20 - 45 min
-
100 - 125
About 15 min
20 - 45 min
Compressive strength, ASTM C109
3 hours after set
24 hours
7 days
28 days
2000 psi (13.8 MPa)
4000 psi (27.6 MPa)
5000 psi (34.5 MPa)
6500 psi (44.8 MPa)
2500 psi (17.2 MPa)
4500 psi (31 MPa)
5500 psi (37.9 MPa)
7500 psi (51.7 MPa)
3000 psi (20.7 MPa)
5000 psi (34.5 MPa)
6000 psi (41.4 MPa)
8000 psi (55.2 MPa)
Slant shear bond strength, ASTM C928
1 day
7 days
1000 psi (6.9 MPa)
1500 psi (10.3 MPa)
1000 psi (6.9 MPa)
1500 psi (10.3 MPa)
1000 psi (6.9 MPa)
1500 psi (10.3 MPa)
Height change, ASTM C1090
1, 3, 7 and 28 days 0 - 0.2% 0 - 0.2% 0 - 0.2%
TABLE 2 Typical Physical Properties
FastSet
All-Crete
Tested as a Repair Material
ASTM C928 R3
Specifications
FastSet
All-Crete
FastSet
All-Crete
Aggregate extension No Aggregate No Aggregate 30 lb (13.6 kg) of -1/2” (-12
mm) gravel
Slump, ASTM C143 > 3” (75 mm) 3” - 6” (75 - 150 mm) 3” - 6” (75 - 150 mm)
Setting time, ASTM C191 Final No requirement 20 - 45 min 20 - 45 min
Compressive strength, ASTM C109
3 hours
24 hours
7 days
28 days
3000 psi (20.7 MPa)
5000 psi (34.5 MPa)
5000 psi (34.5 MPa)
No requirement
3000 psi (20.7 MPa)
5000 psi (34.5 MPa)
6000 psi (41.4 MPa)
8000 psi (55.2 MPa)
3000 psi (20.7 MPa)
5000 psi (34.5 MPa)
6000 psi (41.4 MPa)
8000 psi (55.2 MPa)
Slant shear bond strength, ASTM C928
1 day
7 days
1000 psi (6.9 MPa)
1500 psi (10.3 MPa)
1000 psi (6.9 MPa)
1500 psi (10.3 MPa)
1000 psi (6.9 MPa)
1500 psi (10.3 MPa)
Scaling resistance, ASTM C672 1 lb/ft
3
(5 kg/m
3
) 0.004 lb/ft
3
(0.064 kg/
m
3
)
FastSet
All-Crete