Part Name: Model No: HPE-450-A12S Document Version: A0 PRODUCT SPECIFICATION Release Date: 2013/8/19 Approved by : Checked by : HIGH POWER ELECTRONIC CO., LTD TEL: + 886-2-2659.2535 Fax : +886-2-2659.2265 Prepared by : SIRFA International Co., Ltd.
Switching Power Supply Specifications Subject:Change History of Specification 日期 版本 修訂 頁面 2013/8/19 A0 -- 變 更 內 容 REF NO.
Switching Power Supply Specifications Table of Contents 1 INPUT 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 VOLTAGE FREQUENCY CURRENT INRUSH CURRENT POWER EFFICIENCY LEAKAGE CURRENT POWER FACTOR ErP REQUIREMENT 2 OUTPUT 2.1 2.2 2.3 2.4 2.5 2.6 2.7 REMOTE ON/OFF HOLD-UP TIME POWER GOOD DELAY POWER FAIL DELAY TURN-ON DELAY TIME TRANSIENT OVERSHOOT RISE TIME 3 PROTECTION 3.1 3.2 3.3 OVER VOLTAGE PROTECTION SHORT PROTECTION OVER POWER PROTECTION 4 ENVIRONMENT 4.1 4.2 4.3 4.4 4.5 4.
Switching Power Supply Specifications 6 SAFETY AND EMC REQUIREMENTS 6.
Switching Power Supply Specifications 1. INPUT: 1.1 VOLTAGE MINIMUM NOMINAL MAXIMUM UNITS 207 230 253 Vrms 1.2 FREQUENCY 47Hz ~ 63Hz 1.3 CURRENT 230Vac / 4.0A max. 1.4 INRUSH CURRENT 100A max. when AC input 230Vac and 25℃ cold start. 1.5 POWER EFFICIENCY 72% minimum under the load conditions defined in below table and 230Vac input. Loading Table for Efficiency Measurements 450W(loading shown in Amps) Loading +12V1 +12V2 +5V +3.3V -12V +5Vsb Full 14.65 12.56 12.05 14.73 0.27 2.27 1.
Switching Power Supply Specifications 2. OUTPUT: Voltage +5V +3.3V +12V1 +12V2 -12V +5Vsb *(1) Max load 18.0A 22.0A 21.0A 18.0A 0.3A 2.5A Min load 0.5A 0.3A 0.5A 0.5A 0.0A 0.0A Peak load -- -- 24.0A 21.0A -- 3.0A -- -- *(1) Combined power 120W 360W *(3) Regulation +5,-5% +5,-5% +5,-5% +5,-5% +10,-10% +5,-5% *(2) Ripple & Noise 50mV 50mV 120mV 120mV 120mV 50mV * (1) The continuous total output power is 450W max. ‧The combined power of +5V and +3.3V is 120W max.
Switching Power Supply Specifications 2.2 HOLD-UP TIME 13msec (minimum) at 80% of full load at 230Vac input. 2.3 POWER GOOD DELAY 100-500 msec. 2.4 POWER FAIL DELAY >1 msec. 2.5 TURN-ON DELAY TIME 2000 msec max. At Nominal Line Full Load. 2.6 TRANSIENT OVERSHOOT DC output transient step sizes as below table: Output voltage +5V +3.3V +12V1 +12V2 Max. step size 30% 30% 40% 40% Load-changing repetition rate of 10m seconds. Load slew rated 1.0A/uS and capacitive load as below : +5V +3.
Switching Power Supply Specifications 3.2 SHORT PROTECTION All output to GND. 3.3 OVER POWER PROTECTION Foldback at 110%~150% over peak load. 4. ENVIRONMENT: 4.1 OPERATING TEMP. 0℃ to +40℃ 4.2 STORAGE TEMP. -20℃ to +70℃ 4.3 OPERATING HUMIDITY 20% to 90%, non-condensing 4.4 STORAGE HUMIDITY 5% to 95%, non-condensing 4.5 OPERATING ALTITUDE 0 to 10,000 feet 4.6 STORAGE ALTITUDE 0 to 50,000 feet 5. HI-POT: 5.1 PRIMARY TO SECONDRY 1800Vac for 1 minute 6. SAFETY AND EMC REQUIREMENTS 6.