Port1-4 - These represent the RocketRAID 3530/3540’s Internal Mini-SAS ports. Each
port can support up to 4 SATA hard disks. The RR3530 is 3 ports, and can support up
to 12 disks. The RR3540 is 4 ports, and can support up to 16 hard disks.
BEEP1 – (alarm/speaker): the speaker emits and audible alarm in the case of disk/array
failure.
A1-A4/F1-F4 – LED connections. “A” refers to the disk activity connectors, and
those marked “F” function as disk failure connectors
Note: The RocketRAID 3530 supports 12 disks, and only provides 3 LED connectors
for each function (A1-A3 ,F1-F3).
J17 - This jumper can be used to enable or disable the card’s alarm (BEEP1). The
alarm is enabled by default (the jumper is attached). To disable the alarm, remove the
jumper
J4 - This jumper supports SAF-TE interface (I2C).
J18 (BBU connector) - Connector for battery backup unit (optional part).
Ethernet Port - Ethernet port (U32) for Out of Band Management, support Net Time
Protocol.