3.4.1 Set Alarm Mode Palees
Alarm mode palees allows to mark the targets of certain temperature range with a dierent color
from the rest.
Steps
1. Select Palees from the main menu.
2. Tap the icons to select an alarm rule type.
Table 3-2 Icon Descripon
Icon Alarm Mode Descripon
Above Alarm Set the alarm temperature, and the targets with the
temperature higher than the set value are displayed
in red.
Below Alarm Set the alarm temperature, and targets with the
temperature lower than the set value are displayed in
blue.
Interval Alarm Set the alarm temperature secon (e.g., 90 °C to
150 °C), and targets with the temperature in the
range are displayed in yellow.
Insulaon Alarm Set the alarm temperature secon (e.g., 90 °C to
120 °C), targets with the temperature out of the
secon (e.g., 70 °C or 125 °C) are displayed in purple
or blue.
3. Oponal: Pr
ess
and to select between upper limit and lower limit.
4. Pr
ess
and to adjust the rule temperature.
5. Pr
ess
to exit.
3.4.2 Set Focus Mode Palees
Focus mode palees allows to mark the targets of certain temperature range with fusion palees
and the others with white hot palees.
Steps
1. Select Palees from the main menu.
2. T
ap the icons to select an alarm rule type.
Handheld Thermal Camera G Series User Manual
18