User's Manual

Table Of Contents
3.4.1 Set Alarm Mode Palees
Alarm mode palees allows to mark the targets of certain temperature range with a dierent color
from the rest.
Steps
1. Select Palees from the main menu.
2. Tap the icons to select an alarm rule type.
Table 3-2 Icon Descripon
Icon Alarm Mode Descripon
Above Alarm Set the alarm temperature, and the targets with the
temperature higher than the set value are displayed
in red.
Below Alarm Set the alarm temperature, and targets with the
temperature lower than the set value are displayed in
blue.
Interval Alarm Set the alarm temperature secon (e.g., 90 °C to
150 °C), and targets with the temperature in the
range are displayed in yellow.
Insulaon Alarm Set the alarm temperature secon (e.g., 90 °C to
120 °C), targets with the temperature out of the
secon (e.g., 70 °C or 125 °C) are displayed in purple
or blue.
3. Oponal: Pr
ess
and to select between upper limit and lower limit.
4. Pr
ess
and to adjust the rule temperature.
5. Pr
ess
to exit.
3.4.2 Set Focus Mode Palees
Focus mode palees allows to mark the targets of certain temperature range with fusion palees
and the others with white hot palees.
Steps
1. Select Palees from the main menu.
2. T
ap the icons to select an alarm rule type.
Handheld Thermal Camera G Series User Manual
18