User Manual of DS-1004KI Keyboard V1.1.0 UD.
User Manual of the DS-1004K keyboard Preventive and Cautionary Tips Before connecting and operating your keyboard, please be advised of the following tips: Ensure unit is placed in a well-ventilated, dust-free environment. Keep all liquids away from the keyboard. Please check the power supply to avoid the damage caused by voltage mismatch. Please make sure the keyboard work in the allowed range of temperature and humidity.
User Manual of the DS-1004K keyboard 2 Contents Chapter 1 Product Overview ......................................................................................................................................................... 3 Chapter 2 Device Appearance ....................................................................................................................................................... 5 2.1 Rear Panel Description .................................................................
User Manual of the DS-1004K keyboard 3 Chapter 1 Product Overview DS-1004KI keyboard can be used to control the DVR, the analog dome, the video management platform and the analog matrix. The keyboard is featured in its steady and friendly operation. Multiple Controlling Modes The keyboard controls the DVR, Dome Camera, VMS and Analog Matrix. Controlling modes determine the devices controlled by the keyboard; e.g.
User Manual of the DS-1004K keyboard 4 MENU: Keyboard Configuration Mode. Turn the key to the MENU. Set the keyboard parameters, such as the keyboard address, the RS-485 parameters and the RS-232 parameters. OPERATE: Keyboard Operation Mode. Turn the key to OPERATE. Under this mode, the keyboard can control the DVR, PTZ of the dome camera and the matrix. PROGRAM: Keyboard Function Settings Mode. Turn the key to PROGRAM.
User Manual of the DS-1004K keyboard 5 Chapter 2 Device Appearance 2.1 Rear Panel Description Figure 2-1 The Rear Panel of DS-1004KI Keyboard Notes: The green end with a G identifier on the rear panel is for grounding. Number 1 Physical Interfaces Grounding 2 PTZ-CON (PTZ Control Signal Output) As main keyboard: Connect the dome camera or the RS485 of the PTZ: TA connects to RS485+, and TB connects to RS485-.
User Manual of the DS-1004K keyboard 6 2.2 Front Panel Description Figure 2-2 Top View on DS-1004KI Keyboard Note: Buttons on the keyboard have different functions in different controlling modes. For example, the IRIS+/EDIT button realizes the IRIS+ in PTZ control mode and in the DVR control mode, it is the EDIT button, when pressing, you can edit the combox field. Button Description Lock Switch to change the working mode of the keyboard.
User Manual of the DS-1004K keyboard 7 Button Description NEXT The next item, can be a channel or menu setting field. DVR control mode: change the tab menu LAST The previous item, can be a channel or menu setting field. MON When controlling the VMS or analog matrix, press this button to choose the monitor. CAM MODE Numeric & characters buttons (0-9) CLEAR ENTER IRIS+/EDIT When controlling the VMS or analog matrix, press this button to choose the camera.
User Manual of the DS-1004K keyboard 8 2.4 Typical Wiring Methods Figure 2-3 Connection between the keyboards, the keyboards and the dome camera, the keyboard and the DVRs ① shows the connection of the auxiliary keyboard and the main keyboard. You can connect many auxiliary keyboards to the main keyboard. ② shows the connection between the keyboard and the DVR/NVR. ③ shows the connection of DVRs when they are all connected and controlled by the keyboard.
User Manual of the DS-1004K keyboard 9 Figure 2-4 Connection between the main and auxiliary keyboards, and the keyboards and the dome camera ① shows the connection of the auxiliary keyboard and the main keyboard. You can connect many auxiliary keyboards to the main keyboard. ② shows the connection between keyboard and dome camera. ③ shows the connection between dome cameras when they are all connected and controlled by the keyboard.
User Manual of the DS-1004K keyboard 10 Figure 2-5 Connection between the paralleled keyboards, the keyboards and the dome camera, the keyboard and the DVRs ① shows the connection of keyboard when they are connected to each other to control the dome camera. PTZ-CON interface: TA connects TA, TB connects TB. ③ shows the connection between the keyboard and the dome camera. PTZ-CON TA connects 485+, TB connects 485-. ② shows the connection between the paralleled connected keyboard and DVR/NVR.
User Manual of the DS-1004K keyboard 11 Figure 2-6 Connection between the keyboard and the analog matrix The RS-232 interface of the DS-1004KI keyboard uses the DB9 interface. And the definition of pins of DB9 interface is written in the table below. No. 1 2 3 4 5 6 7 8 9 Name DCD RXD TXD DTR GND DSR RTS CTS RI Function -Receiving Data Transmitting Data -Grounding ----- The DS-1004KI keyboard uses RS-232 interface, the RS-232 interface connects the keyboard control interface on the analog matrix.
User Manual of the DS-1004K keyboard 12 Figure 2-7 Connection between the keyboard and the VMS The DS-1004KI keyboard controls the VMS, and to control it, you need to configure the VMS with the cascading configuration tool. Please refer to the manual of the VMS. The DVR-CON TA connects the sixth pin of RS-485 interface on the VMS side, and the DVR-CON TB connects the fifth pin of RS485 interface on the VMS side.
User Manual of the DS-1004K keyboard 13 Chapter 3 Keyboard Operation 3.1 Controlling DVR by Keyboard Setting the Keyboard Parameters to Control DVR Once the keyboard is connected to the DVR, it can be used just as the front panel of the DVR. The joystick can move the cursor. Before you start: Check the connection between the DVR and the Keyboard. TA and TB of CON1 on the keyboard connect to D+ and D- of the DVR. The following figure shows the simplest way of connection between a DVR and keyboard.
User Manual of the DS-1004K keyboard 14 Figure 3-3 Choose MODE as DVR 2. Press the numeric button and press SITE to connect the DVR. Note: The keyboard identifies the DVR by SITE value, and the SITE value must be exactly the same with the device number. E.g. the device number is 1, press the numeric button 1 and press SITE button again. The keyboard only connects the DVR with device number ranging from 1 to 255. 3.
User Manual of the DS-1004K keyboard To call the preset/patrol/pattern: Steps: 6. Press IRIS-/PTZ button to enter the PTZ control interface of the DVR 7. Press the PRESET/PATROL/PATTERN button. 8. Press the numeric button. 9. Press ENTER button.
User Manual of the DS-1004K keyboard 16 3.2 Controlling Dome Cameras by Keyboard Setting the Keyboard Parameters to Control Dome Camera Before you start: Check the connection between the keyboard and dome camera. The TA and TB interfaces of CON of keyboard should be connected to the RA and RB interfaces of the dome camera respectively. The following figure shows the simplest way of connection between a dome camera and keyboard. Figure 3-5 Dome and Keyboard Connection Steps: 1.
User Manual of the DS-1004K keyboard 17 The parameters include the protocol, baud rate, data bit, stop bit, and parity. 4. When the LED screen shows COPYALL, you can choose YES or NO. When you choose YES, the parameters you just set will be copied to other dome cameras connected. 5. Press Enter button to confirm your settings. 6. Turn the key to the OPERATE item to control the dome camera. Dome Camera Control Operation The keyboard mainly controls the PTZ function of the dome camera.
User Manual of the DS-1004K keyboard 18 3.3 Controlling the VMS by Keyboard Setting the Keyboard Parameters to Control VMS There is no RS485 interface for the VMS, you can use the RS-485-to-RS-232 converter to connect the VMS. 1. Turn the key to the MENU item, and press the Mode button to select the Matrix as the controlled device. 2. Press the SITE button to set the device identifier. Note: The keyboard identifies the controlled device by the device address.
User Manual of the DS-1004K keyboard 19 Steps: 1. Press numeric button 1 and press MON. 2. Press numeric button 2 and press CAM-G button. 3. Press HOLD button. 4. Press RUN button. 5. Press LAST button. To set the preset, turn the key to the PROGRAM mode, press the numeric button and press CAM button to choose camera. Press numeric button and press preset button the set preset.
User Manual of the DS-1004K keyboard 20 3.4 Controlling the Analog Matrix by Keyboard Setting the Keyboard Parameters to Control Analog Matrix The RS-232 communication is used when the DS-1004KI keyboard is controlling the analog matrix system. And the following parameters must be correctly configured for the RS-232 port: protocol, baud rate, data bit, stop bit and parity. ZT-1.0, ZT-2.0, EXTRON and CREATOR protocols are supported by the keyboard.
User Manual of the DS-1004K keyboard 21 Appendix 1:Specification Hikvision Model DS-1004KI Joystick Four-Axis Serial Port RS485 and RS232 Working Temperature -10℃- +55℃ Working Humidity 10%-90% Power Supply 12VDC Power Consumption Dimension (W×D×H) Weight ≤10W 434×163×43mm ≤1.
User Manual of the DS-1004K keyboard First Choice for Security Professionals Hikvision 22