User Manual

Network Security Control Panel User Manual
4
public partition are in the arming status.
The public partition is disarmed automatically when any of partitions linked with
the public partition is in the disarming status.
The user also can arm or disarm the public partition independently.
Limit
For the public partition of multiple security control panels, up to 2 other partitions
can be linked to it.
1.2.3 Zone
Definition
Zone is a basic concept in the security control panel system. It refers to a protection
area in the system, and is regarded as the maximum recognizable unit to distinguish
the alarm event. As a connection between the detector and the security control
panel, it determines whether to trigger an alarm according to the resistance value
of the alarm controller.
1.2.4 Zone Type
24-Hr Audible Alarm Zone
The detectors of this zone are in 24 hours’ alert condition, which will not
be affected by arming and disarming operation or be bypassed. When
the zone detects alarm events, the sound and light alarming prompt will
be triggered on the keyboard. The siren output will be triggered when
the siren is linked, meanwhile the generated event report will be
uploaded to the center receiver, and the zone alarm status can be
checked on the client. This zone type is generally applied to emergency
button, smoke detector and glass break detector.
24-Hr Silent Alarm Zone
The detectors of this zone are in 24 hours’ alert condition, which will not
be affected by arming and disarming operation or be bypassed. When
the zone detects alarm events, the sound and light alarming prompt will
be triggered on the keyboard. The siren output will be triggered when
the siren is linked, meanwhile the generated event report will be
uploaded to the center receiver, and the zone alarm status can be
checked on the client. This zone type is generally applied to the sites
equipped with emergency button (e.g. bank, jewelry counter).
24-Hr Auxiliary alarm zone
The detectors of this zone are in 24 hours’ alert condition, which will not
be affected by arming and disarming operation or be bypassed. When