the zone detects alarm events, the sound and light alarming prompt will
be triggered on the keyboard. The siren output will be triggered when
the siren is linked, meanwhile the generated event report will be
uploaded to the center receiver (the uploaded report is different with
the report of 24-Hr Audible Alarm Zone), and the zone alarm status can
be checked on the client. Generally, it is used to define a zone with
emergency button, or a zone used to monitor devices, such as water
detector or temperature sensor.
Fire Alarm Zone
The detectors of this zone are in 24 hours’ alert condition, which will not
be affected by arming and disarming operation or be bypassed. When
the zone detects alarm events, the sound and light alarming prompt will
be triggered on the keyboard. The siren output will be triggered when
the siren is linked, meanwhile the generated event report will be
uploaded to the center receiver (the uploaded report is different with
the report of 24-Hr Audible Alarm Zone), and the zone alarm status can
be checked on the client. This zone type is generally used in the smoke
detector.
Perimeter Zone/Instant Zone
When the system is armed, the detectors of this zone will be in alert
condition. The zone will be immediately triggered when it detects alarm
event, and the system will alarm instantly without any delay time. When
the system is disarmed, if the zone hasn’t recovered, a zone alarm
recovered report will be automatically reported to the center receiver,
and the zone turns to fault status. This zone type can be assigned to all
the detectors, especially the detectors that used to protect doors and
windows.
Entering/Exiting Delayed Zone
The system will provide exiting delay after performing the arming
operation. The zone will not alert during exiting delay and the detectors
of this zone will be in alert condition at the end of exiting delay. When
the system is in arm away or arm stay, it will provide enter delay when
the zone detects alarm event. Users must disarm the system by the end
of enter delay, if not, the zone alarm will be triggered. When the system
is in arm instant, the alarm will occur instantly after the zone detects
alarm event, and the system will not provide enter delay. Both the exiting
delay and enter delay can be programmable set. This zone type is mainly
used in entrance/exit route (e.g. front door/main entrance), which is a
key route to operate keyboard for users.