Demonstration:
E.g., the installer password
is 012345,RS-485 address
is 09.
LCD Display
Enter the installer
password: [0] [1] [2] [3] [4]
[5].
xxxxxx*Project09
Press [*] to enter the
working mode.
Press[Project].
Enter[0] [9] as the address
of the RS-485 expander
Press [#] to confirm the
operation.
If the operation is successful,
Operation Succeeded
If the operation is failed,
Operation Failed
2.1.18 Control Panel Programming Operation
Function: The control panel can be configured via alarm keypad operation.
Entering Programming Mode
Command:[Installer Password] + [*] + [0] + [#]