MOTION
AUTO FLIP ON
PROPORTIONAL PAN ON
PARK TIME 5
PARK ACT NONE
SCAN SPEED 28
IMAGE FREEZE OFF
DOME SPEED 6
BACK EXIT
Figure 3-8 PTZ Configuration
2. Move the cursor to the PARK TIME, and set the value ranging from 5 to 720 seconds.
3. Move the cursor to the PARK ACT, and the action can be set as preset 1 to 8, pattern 1 to 5,
patrol 1 to 10, pan scan, tilt scan, random scan, frame scan, panoramic scan, day mode, night
mode, patrol-d or none.
If no control signal is received after the park time under the following circumstances, no park
actions will be performed: in the process of performing dome actions by calling special presets.