User Manual

46
Select a PRIVACY area. Set the DISPLAY status as INV, MOSAIC,
COLOR, or OFF. Click up/down/left/down button to define the
position and size of the area.
VOLTAGE DETECTION: Detect whether the voltage is overvoltage
or undervoltage.
When the input voltage is 30 % lower than the calibrated voltage,
the UNDERVOLTAGE flashes on the screen.
When the input voltage is 30 % higher than the calibrated voltage,
the OVERVOLTAGE flashes on the screen.
Note:
Camera type IV, and type V do not support VOLTAGE DETECTION.
DEFECT: Defective pixels are pixels in a CCD or CMOS image
sensor in digital cameras, in which the defective pixels fail to
sense light levels correctly. This series of camera supports
defective pixel correction. Move the cursor to DEFECT and click
Iris+ to enter the defective pixel correction interface.
LIVE DPC, and STATIC DPC are adjustable in this section.
DEFECT
1. LIVE DPC ON
2. STATIC DPC ON
3. RETURN RET
Figure 3. 11 Defect