User Manual

Table Of Contents
Figure 6-7 Set Rule
5. Oponal: You can set the parameters of mulple areas by repeang the above steps.
6. For the arming schedule sengs, refer to Set Arming Schedule . For the linkage method
sengs, refer to Linkage Method Sengs .
7. Click Save.
6.2.11 Set Object Removal
Detecon
It detects whether the objects are removed from the pre-dened detecon region, such as the
exhibits on display. If it occurs, the device can take linkage
acons and the sta can take measures
to reduce property loss.
Steps
1. Go to Conguraon → Event → Smart Event → Object Removal Detecon .
2. Check Enable.
3. Select a Region. For the region
sengs, see Draw Area .
4. Set the rule.
Sensivity
It stands for the percentage of the body part of an acceptable target that leaves
the pre-dened region.
Sensivity = 100 – S1/ST*100
S1 stands for the target body part that leaves the
pre-dened region. ST stands
for the complete target body.
Example: If you set the value as 60, a target is possible to be counted as a
removed object only when 40 percent body part of the target leaves the region.
Threshold The threshold for the me of the objects removed from the region. If you set
the value as 10, alarm is triggered aer the object disappears from the region
for 10s.
5. Oponal: Repeat the above steps to set more regions.
Network Camera User Manual