Network Camera User Manual
40
6.1.4 Set Exception Alarm
Exception such as network disconnection can trigger the device to take corresponding action.
Steps
1. Go to Configuration Event Basic Event Exception.
2. Select Exception Type.
The HDD storage is full.
Error occurs in HDD.
The device is offline.
The IP address of current device is same as that of other device in the
network.
Incorrect user name or password is entered.
The power supply voltage is fluctuating.
3. Refer to Linkage Method Settings for setting linkage method.
4. Click Save.
6.1.5 Set Alarm Input
Alarm signal from the external device triggers the corresponding actions of the current device.
Before You Start
Make sure the external alarm device is connected. See Quick Start Guide for cables connection.
Steps
1. Go to Configuration Event Basic Event Alarm Input.
2. Check Enable Alarm Input Handing.
3. Select Alarm Input NO. and Alarm Type from the dropdown list. Edit the Alarm Name.
4. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
5. Click Copy to... to copy the settings to other alarm input channels.
6. Click Save.