3. Select one Region. For the region settings, refer to Draw Area.
4. Set the detection target, sensitivity and the target validity.
It stands for the percentage of the body part of an acceptable target
that goes across the pre-defined region. Sensitivity = 100 - S1/ST ×
100. S1 stands for the target body part that goes across the
pre-defined region. ST stands for the complete target body. The
higher the value of sensitivity is, the more easily the alarm can be
triggered.
Human and vehicle are available. If the detection target is not
selected, all the detected targets will be reported, including the
human and vehicle.
If you set a higher validity, the required target features should be
more obvious, and the alarm accuracy would be higher. The target
with less obvious features would be missing.
Figure 6-6 Set Rule
5. Optional: You can set the parameters of multiple areas by repeating the above steps.
6. For the arming schedule settings, refer to Set Arming Schedule. For the linkage method settings,
refer to Linkage Method Settings.
7. Click Save.
6.2.9 Set Region Exiting Detection
It is used to detect objects exiting from a pre-defined virtual region. If it occurs, the device can
take linkage actions.
Steps
1. Go to Configuration Event Smart Event Region Exiting Detection